Product |
|
|
'CG.AR.M20.BN.C.16.K01' är nu tillagd på din bevakniningslista.
CG.AR.M20.BN.C.16.K01` finns redan på din bevakniningslista.
|
For armored cables, Brass nickel-plated, Thread M20, Seal chloroprene, Ex d, Ex e and Ex tb certified, Suitable for operation in Zone 1, Zone 2, Zone 21 and Zone 22, Suitable for operation in Class I, Zone 1/2/22, Suitable for operation in Class I, Division 2 when installed in accordance with NEC501.10(B)(2), Degree of protection IP66 / IP68, UL Type 4X, Packaging unit: 1 piece, kit with accessories, Ambient temperature: -40 ... 80 °C (-40 ... 176 °F) washer gasket -50 ... 80 °C (-58 ... 176 °F)pa |
|
|
|
'CG.AR.M25.BN.C.16.K01' är nu tillagd på din bevakniningslista.
CG.AR.M25.BN.C.16.K01` finns redan på din bevakniningslista.
|
For armored cables, Brass nickel-plated, Thread M25, Seal chloroprene, Ex d, Ex e and Ex tb certified, Suitable for operation in Zone 1, Zone 2, Zone 21 and Zone 22, Suitable for operation in Class I, Zone 1/2/22, Suitable for operation in Class I, Division 2 when installed in accordance with NEC501.10(B)(2), Degree of protection IP66 / IP68, UL Type 4X, Packaging unit: 1 piece, kit with accessories, Ambient temperature: -40 ... 80 °C (-40 ... 176 °F) washer gasket -50 ... 80 °C (-58 ... 176 °F)pa |
|
|
|
'CG.EM.M16.BN.C.16.K01' är nu tillagd på din bevakniningslista.
CG.EM.M16.BN.C.16.K01` finns redan på din bevakniningslista.
|
For shielded EMC cables without armor, Brass nickel-plated, Thread M16, Seal chloroprene, Ex db, Ex eb and Ex tb certified, Suitable for operation in Zone 1, Zone 2, Zone 21 and Zone 22, Degree of protection IP66 / IP68, UL Type 4X, Packaging unit: 1 piece, kit with accessories, Ambient temperature: -40 ... 80 °C (-40 ... 176 °F) washer gasket -40 ... 80 °C (-40 ... 176 °F), Cable type: non-armored shielded EMC cables, Thread size (TD): M16, Cable gland: brass, nickel-platedpa |
|
|
|
'CG.EM.M20.BN.C.18.K01' är nu tillagd på din bevakniningslista.
CG.EM.M20.BN.C.18.K01` finns redan på din bevakniningslista.
|
For shielded EMC cables without armor, Brass nickel-plated, Thread M20, Seal chloroprene, Ex db, Ex eb and Ex tb certified, Suitable for operation in Zone 1, Zone 2, Zone 21 and Zone 22, Suitable for operation in Class I, Zone 1/2/22, Suitable for operation in Class I, Division 2 when installed in accordance with NEC501.10(B)(2), Degree of protection IP66 / IP68, UL Type 4X, Packaging unit: 1 piece, kit with accessoriespa |
|
|
|
'CG.EM.M25.BN.C.16.K01' är nu tillagd på din bevakniningslista.
CG.EM.M25.BN.C.16.K01` finns redan på din bevakniningslista.
|
For shielded EMC cables without armor, Brass nickel-plated, Thread M25, Seal chloroprene, Ex db, Ex eb and Ex tb certified, Suitable for operation in Zone 1, Zone 2, Zone 21 and Zone 22, Suitable for operation in Class I, Zone 1/2/22, Suitable for operation in Class I, Division 2 when installed in accordance with NEC501.10(B)(2), Degree of protection IP66 / IP68, UL Type 4X, Packaging unit: 1 piece, kit with accessoriespa |
|
|
|
'CG.EM.NPT1/2.BN.C.18.K01' är nu tillagd på din bevakniningslista.
CG.EM.NPT1/2.BN.C.18.K01` finns redan på din bevakniningslista.
|
For shielded EMC cables without armor, Brass nickel-plated, Thread NPT 1/2'', Seal chloroprene, Ex db, Ex eb and Ex tb certified, Suitable for operation in Zone 1, Zone 2, Zone 21 and Zone 22, Suitable for operation in Class I, Zone 1/2/22, Suitable for operation in Class I, Division 2 when installed in accordance with NEC501.10(B)(2), Degree of protection IP66 / IP68, UL Type 4X, Packaging unit: 1 piece, kit with accessoriespa |
|
|
|
'CG.NA.M16.BN.C.16.K01' är nu tillagd på din bevakniningslista.
CG.NA.M16.BN.C.16.K01` finns redan på din bevakniningslista.
|
For cables without armor, Brass nickel-plated, Thread M16, Seal chloroprene, Ex db, Ex eb and Ex tb certified, Suitable for operation in Zone 1, Zone 2, Zone 21 and Zone 22, Degree of protection IP66, Packaging unit: 1 piece, kit with accessories, Ambient temperature: -40 ... 80 °C (-40 ... 176 °F) washer gasket -40 ... 80 °C (-40 ... 176 °F), Cable type: non-armored cables, Thread size (TD): M16, Cable gland: brass, nickel-plated, Washer gasket: aramid fibers bonded with NBR, O-Ring: chloroprenepa |
|
|
|
'CG.NA.M20.BN.C.16.K01' är nu tillagd på din bevakniningslista.
CG.NA.M20.BN.C.16.K01` finns redan på din bevakniningslista.
|
For cables without armor, Brass nickel-plated, Thread M20, Seal chloroprene, Ex db, Ex eb and Ex tb certified, Suitable for operation in Zone 1, Zone 2, Zone 21 and Zone 22, Suitable for operation in Class I, Zone 1/2/22, Suitable for operation in Class I, Division 2 when installed in accordance with NEC501.10(B)(2), Degree of protection IP66 / IP68, UL Type 4X, Packaging unit: 1 piece, kit with accessories, Ambient temperature: -40 ... 80 °C (-40 ... 176 °F) washer gasket -40 ... 80 °C (-40 ... 176 °F)pa |
|
|
|
'CG.NA.M20S.BN.C.16.K01' är nu tillagd på din bevakniningslista.
CG.NA.M20S.BN.C.16.K01` finns redan på din bevakniningslista.
|
For cables without armor, Brass nickel-plated, Thread M20, Seal chloroprene, Ex db, Ex eb and Ex tb certified, Suitable for operation in Zone 1, Zone 2, Zone 21 and Zone 22, Suitable for operation in Class I, Zone 1/2/22, Suitable for operation in Class I, Division 2 when installed in accordance with NEC501.10(B)(2), Degree of protection IP66 / IP68, UL Type 4X, Packaging unit: 1 piece, kit with accessories, Ambient temperature: -40 ... 80 °C (-40 ... 176 °F) washer gasket -40 ... 80 °C (-40 ... 176 °F)pa |
|
|
|
'CG.NA.M20S.SS.C.16.K01' är nu tillagd på din bevakniningslista.
CG.NA.M20S.SS.C.16.K01` finns redan på din bevakniningslista.
|
For cables without armor, Stainless Steel, Thread M20, Seal chloroprene, Ex db, Ex eb and Ex tb certified, Suitable for operation in Zone 1, Zone 2, Zone 21 and Zone 22, Suitable for operation in Class I, Zone 1/2/22, Suitable for operation in Class I, Division 2 when installed in accordance with NEC501.10(B)(2), Degree of protection IP66 / IP68, UL Type 4X, Packaging unit: 1 piece, kit with accessories, Ambient temperature: -40 ... 80 °C (-40 ... 176 °F) washer gasket -40 ... 80 °C (-40 ... 176 °F)pa |
|
|
| |